HomeProductsSample Preparation EquipmentFully Automated Purge and Trap System
  • Fully-Automated-Purge-and-Trap-System
  • Fully-Automated-Purge-and-Trap-System
  • Fully-Automated-Purge-and-Trap-System
  • Fully-Automated-Purge-and-Trap-System

Fully Automated Purge and Trap System

The PTC-V is a state-of-the-art, fully automated Purge and Trap (P&T) concentrator integrated with a 100-position autosampler, engineered for the precise extraction of Volatile Organic Compounds (VOCs) from solid and liquid samples.

Features:
Universal & Fully Automated
Superior Thermal & Cooling Technology
Maximum Contamination & Moisture Control

Introduction

Parameters

VOC Sample Preparation with Built-in 100-Position Autosampler

Designed for seamless hyphenation with any brand of Gas Chromatography (GC) or Gas Chromatography-Mass Spectrometry (GC-MS) systems, the PTC-V delivers unparalleled analytical efficiency. Thanks to its patented moisture removal technology, precise Electronic Flow Control (EFC/AFC), and superior trap desorption rates, it minimizes water interference and ensures highly reproducible, stable, and accurate VOC analysis.

Fully-Automated-Purge-and-Trap-System

Applications & Compliance

Ideal for high-throughput laboratories, the PTC-V is widely used in:

  • Environmental Analysis: Drinking water, wastewater, and soil organic pollutant testing.
  • Food & Beverage: Analysis of volatile flavor compounds and odor components.

The system fully complies with stringent environmental analytical standards, including:

  • HJ639-2012 (Water Quality – Determination of VOCs by P&T/GC-MS)
  • HJ686-2014 (Water Quality – Determination of VOCs by P&T/GC)
  • HJ605-2011 (Soil and Sediment – Determination of VOCs by P&T/GC-MS)

Key Features

Universal & Fully Automated

Universal Compatibility: Plug-and-play integration with any GC or GC-MS brand on the market.

Unattended Operation: Simply load vials into the 100-position tray; the comprehensive software handles all operations automatically, ensuring exceptional sample reproducibility.

Automated Internal Standards: Automatically adds internal standards to simplify workflows.

Intuitive Touchscreen: A large, built-in LCD touchscreen allows for real-time monitoring of temperatures and operational commands.

Smart Synchronization: Provides a synchronous interface to simultaneously start the GC and workstation upon injection.

Superior Thermal & Cooling Technology

  • Advanced Peltier Cooling: The analytical trap utilizes thermoelectric (Peltier) cooling combined with air cooling, achieving temperatures as low as -30°C (at 20°C ambient) to satisfy highly demanding low-temperature enrichment requirements.
  • Ultra-Fast Desorption: Direct resistance heating of the trap ensures a blistering heating rate of >3000°C/min, maximizing peak sharpness and resolution.

Maximum Contamination & Moisture Control

  • Patented Moisture Management: Significantly reduces the transfer of water vapor to the GC/GC-MS, protecting your analytical columns and detector.
  • Smart Foam Sensor: Built-in sensor detects foaming inside the purge tube, instantly protecting the sample lines and the entire analytical system from contamination.
  • Inert Sample Pathways: All sample lines are constructed from PEEK or silanized inert stainless steel to eliminate carryover and active sites.
  • Zero Cold Spots: All transfer lines and the 6-port valve are temperature-controlled, eliminating cold spots and preventing sample loss.
  • Isolated Backflush: Trap and purge tube backflush gas paths are separated. Desorbed compounds from the trap are physically prevented from flowing back into the purge tube, eliminating cross-contamination.
  • Heated Water Rinse: Supports hot distilled water rinsing of lines and the purge tube, alongside customizable cleaning cycles for both the sampling needle and purge tube.
  • Direct Solid Sample Processing: Solid sample vials can be heated and injected with distilled water directly for in-vial magnetic stirring and purging.

Operating Conditions

  • Power Supply: 220VAC ±22VAC, 50Hz ±0.5Hz
  • Backflush Carrier Gas Pressure: ≤ 0.4 MPa
  • Ambient Temperature: +5°C to +35°C
  • Relative Humidity: ≤ 85%

Technical Specifications

Parameter Specification
Sample Capacity 100 positions (compatible with standard 40ml VOA vials)
Flow Control Auto Flow Controller (AFC), Range: 5 ml/min to 500 ml/min
Internal Standard Automated addition supported
Cooling Technology Thermoelectric (Peltier) cooling; Minimum temp: -30°C
Trap Desorption Temp 50°C to 400°C (Heating rate >3000°C/min; cools from 250°C to 35°C in <90s)
Purge Tube Temp Ambient to 90°C (Accuracy: ±1°C)
Transfer Line Temp 50°C to 250°C (Accuracy: ±1°C)
6-Port Valve Temp 50°C to 220°C (Accuracy: ±1°C)
Moisture Trap Temp Ambient to 400°C
Sample Needle Temp 50°C to 220°C (Accuracy: ±1°C)
Rinse Water Temp Ambient to 90°C (Accuracy: ±1°C)
Solid Sample Setup Heating: Ambient to 90°C (±1°C); Mixing: 5ml water with magnetic stirring
Glassware 5ml fritted purge tube (Standard); 25ml purge tube (Optional)
Trap Dimensions Stainless steel, Φ3mm × 180mm × 0.1mm thickness
Timing Range 1 sec to 99 min 59 sec (Timing error: <0.1%)
Max Gas Pressure ≤ 0.6 MPa
Sync Signal Output Dual 1-2 second switch outputs
Max Power < 1000 VA
Dimensions (H×W×D) 560 mm × 605 mm × 860 mm